6 - 33
6 Programless Communications
E5C-T Digital Controllers Programmable Type Communications Manual (H186)
6-4 Connecting to CP-series PLCs
6
6-4-5 Checking Operation
With the default settings, the following parameters are set for the download areas.
(2) We will initialize the download areas with the set values from the E5CC-T Controllers.
The download areas have not been initialized, so we will initialize them with the set values
from the E5CC-T Controllers. Double-click D0025 (Request Flag) in the PLC Memory Win-
dow. The following dialog box is displayed. Enter 2 (Initialize Download Areas) and click the
OK Button.
No.0 No.1 No.2 Parameter Value
D0025 D0095 D0165 Request Flag (fixed) 1 (0001 hex)
D0026 D0096 D0166 Operation Command Code (fixed) 0 (0000 hex)
D0027 D0097 D0167 Fixed SP 0 (0000 hex)
D0028 D0098 D0168 PID 1 Proportional Band 80 (0050 hex)
D0029 D0099 D0169 PID 1 Integral Time 233 (00E9 hex)
D0030 D0100 D0170 PID 1 Derivative Time 40 (0028 hex)
D0031 D0101 D0171 Program 0 Alarm Value 1 0 (0000 hex)
D0032 D0102 D0172 Program 0 Alarm Upper Limit 1 0 (0000 hex)
D0033 D0103 D0173 Program 0 Alarm Lower Limit 1 0 (0000 hex)
D0034 D0104 D0174 Program 0 Alarm Value 2 0 (0000 hex)
D0035 D0105 D0175 Program 0 Alarm Upper Limit 2 0 (0000 hex)
D0036 D0106 D0176 Program 0 Alarm Lower Limit 2 0 (0000 hex)
D0037 D0107 D0177 Heater Burnout Detection 1 0 (0000 hex)
D0038 D0108 D0178 Process Value Input Shift 0 (0000 hex)
D0039 D0109 D0179 Wait Band 0 (0000 hex)
D0040 D0110 D0180 Standby Time 0 (0000 hex)
D0041 D0111 D0181 Program SP Shift Value 0 (0000 hex)
D0042 D0112 D0182 Program 0 Segment 0 SP 0 (0000 hex)
D0043 D0113 D0183 Program 0 Segment 0 Time 0 (0000 hex)
D0044 D0114 D0184 Program 0 Segment 1 SP 0 (0000 hex)
D0045 D0115 D0185 Program 0 Segment 1 Time 0 (0000 hex)
D0046 D0116 D0186 Program 0 Segment 2 SP 0 (0000 hex)
D0047 D0117 D0187 Program 0 Segment 2 Time 0 (0000 hex)
D0048 D0118 D0188 Program 0 Segment 3 SP 0 (0000 hex)
D0049 D0119 D0189 Program 0 Segment 3 Time 0 (0000 hex)
D0050 D0120 D0190 Program 0 Segment 4 SP 0 (0000 hex)
D0051 D0121 D0191 Program 0 Segment 4 Time 0 (0000 hex)
D0052 D0122 D0192 Program 0 Segment 5 SP 0 (0000 hex)
D0053 D0123 D0193 Program 0 Segment 5 Time 0 (0000 hex)
D0054 D0124 D0194 Program 0 Segment 6 SP 0 (0000 hex)
D0055 D0125 D0195 Program 0 Segment 6 Time 0 (0000 hex)
D0056 D0126 D0196 Program 0 Segment 7 SP 0 (0000 hex)
D0057 D0127 D0197 Program 0 Segment 7 Time 0 (0000 hex)
D0058 D0128 D0198 Program 0 Segment 8 SP 0 (0000 hex)
D0059 D0129 D0199 Program 0 Segment 8 Time 0 (0000 hex)
D0060 D0130 D0200 Program 0 Segment 9 SP 0 (0000 hex)
D0061 D0131 D0201 Program 0 Segment 9 Time 0 (0000 hex)
· · · · · · · · · · · · · · ·
D0069 D0139 D0209 Nothing assigned.